ARCHITECTURAL SPECIFICATIONS
OVERHEAD COILING SHUTTERS
PART 1 - GENERAL
1.01 SUMMARY
- Section includes exterior overhead Roll-Up storm and security shutters.
1.02 SUBMITTALS
- Product Data: Submit manufacturer's complete product data for all specified components, including specifications, finish information and installation instructions.
- Shop Drawings: Submit shop drawings showing layout, sizes and types, product materials, components and accessories, fabrication data, operation and wiring diagrams for motor driven operators, finishes, rough-in dimensions, anchorage and installation requirements and details.
- Samples: Manufacturer's standard array of colors for selection by Architect.
- Quality Assurance Submittals:
- Test Reports: Certified test reports showing compliance with specified requirements.
- Certificates: Manufacturer's certification that design criteria meets specified requirements.
- Operating and Maintenance Instructions: Submit detailed maintenance requirements and operating instructions.
- Warranty: Submit specified warranty documents.
1.03 QUALITY ASSURANCE
- Installer Qualifications:
- Use only manufacturer's factory trained installers or qualified licensed installers approved by shutter manufacturer.
- Regulatory Requirements:
- Comply with all local and governing code requirements.
- Unless required otherwise, fabricate to withstand wind loads that carry same rating as component and cladding of walls.
- Pre-Installation Conference: Conduct a pre-installation meeting to verify project installation and coordination requirements, field conditions, and manufacturer instructions.
1.04 DELIVERY, STORAGE AND HANDLING
- Deliver components in manufacturer's original, unopened, undamaged containers with identification labels intact. Store components protected from harmful weather conditions and damage from other construction activity.
1.05 PROJECT CONDITIONS
- Field Measurements: Verify actual measurements of openings by field measurements before fabrication. Show recorded measurements on shop drawings.
1.06 WARRANTY
- Manufacturer's Warranty: Submit, for Owner's acceptance, manufacturer's standard warranty document executed by an authorized company official.
- Warranty period: ______________years.
(Specifier Note: Refer to manufacturer's product data and /or consult with manufacturer's representative for warranty information / requirements).
PART 2 - PRODUCTS
(Specifier Note: Typically in the following, where items occur in brackets ( ) select item desired for Project).
2.01 MANUFACTURER
- Roll-a-way, Inc., 10601 Oak St. N.E.,
St. Petersburg, FL 33716
(727) 576-1143, (800) 683-9505,
FAX (727) 579-9410
2.02 MATERIALS
- Shutter Components:
- Slat Types:
(Specifier Note: Select one of the material a. selections following).
- PVC Slats: Exterior type UV stabilized extruded polyvinyl chloride; Style: (System I, II curved P55). Color: (white) (ivory) (beige) (gray).
- Aluminum Foam-Filled Slats: Aluminum, 3005 H26 alloy, with polyurethane foam insulation core. (Mini aluminum AF150) (System I,II AF200). Color: (white) (ivory) (bronze) electrostatically applied paint.
- Aluminum Extruded Double Wall Slats: Aluminum, 6063-T6 alloy. Color: (beige) (white) (ivory) (bronze) electrostatically applied paint.
- Patented End Retention Extruded on PVC with Rebar Slats
- Bottom Slat: Extruded aluminum, 6063-T6 alloy, 0.050 inch wall thickness.
- Operation: (Manual) (Motor operated).
- Manual operator type: (Pull strap-coiler) (3/1 crank with strap-coiler) (Gear and crank handle).
(Specifier Note: Select a. above or a. below to coordinate with selection of 3.above).
- Electric Motor operator type: Single phase 110V-60Hz, UL recognized. Motor Model / Size_______. Provide back-up battery power pack. Provide manual override capability allowing manual operation in case of power outage.
(Specifier Note: Battery pack and manual override capability above are optional features, delete if not required).
- Side Frames: Die-cast aluminum, (4) (5) (6) sided.
- Box Cover (hood): Roll formed aluminum; .036 inch thickness, 3105-H14 alloy. (4) (5) (6) sided design.
- Track Guides: Aluminum extrusions; 6063-T6. Provide manufacturer's standard (System I track - 3 inch), (System I track - 3 inch, End retention System), (System II track - 2 1/2 inch), (System II ER - 2 1/2 inch)
- Mounting: (Jamb) (Surface) (Buildout).
- Purlin (stormbar) Assembly: Aluminum extrusions, 6005-T5 or 6063-T6 alloy. 3.0", 4.0" with or without I beam inserts, for fixed or removable application.
- Slat Hangers: Stainless steel spring design (Powder Coated).
- Reels: (Aluminum, 6063-T6 alloy - round & octogonal).
- Slat Reinforcement ReBAR: (Extruded aluminum, 6005-T5 alloy).
2.03 SHOP FINISH
- Side Box Cover Frames and Track: (Electrostatically applied - ESP - paint finish AMAA 2603).
- Color: (To match slats) (As selected by Architect).
PART 3 - EXECUTION
3.01 EXAMINATION
- Verify conditions of substrates to determine if acceptable for shutter installation in accordance with manufacturer's instructions. Correct all unsatisfactory conditions prior to commencing shutter installations.
3.02 INSTALLATION
- Install track and all shutter components to comply with project shop drawings and manufacturer's written installation requirements.
- Where metal surfaces are in contact with masonry, concrete or dissimilar metals, protect with manufacturer's recommended isolation coatings or tape.
- After installation, lubricate, test and adjust shutters to operate properly and free from distortion.
3.03 CLEANING
- Clean installed components in accordance with manufacturer's instructions prior to Owner's acceptance. Properly remove from the site all debris remaining from this installation.
- Inadequate surface cleaning will result in corrosion formation & potential structural damage.
3.04 PROTECTION
- Comply with manufacturer recommendations and protect completed shutter installations from damage during remaining construction so as not to void warranty.
END OF SECTION
|